Forensic engineering expert services
Impartial expert opinions for courts and legal disputes (register no. 291469).
DetailsType at least two characters. Press Esc to close.
Cracks, damage, load-bearing questions and seismic assessment — from the visible symptom to the cause, and from there to the solution.
Cracks, damage, load-bearing capacity and the assessment of existing structures; cause-and-effect analysis with repair and strengthening proposals. Lead structural designer authorisation (T).
A structural opinion is only worth having if it does more than describe the defect: it has to explain what caused it, whether it is dangerous now and what the proportionate intervention is. The investigation always covers the structural system as a whole — a crack is rarely an isolated phenomenon.
The practical expert work is complemented by a university research background: at Széchenyi István University I work on the seismic vulnerability of the existing building stock, on rapid visual screening (RVS) methodology and on pushover analysis.
On the basis of photographs and a description of the problem we estimate how deep an investigation is justified.
Structural survey, recording of the crack pattern, measurements and opening up where required.
Verification of load-bearing capacity, modelling and clarification of the cause-and-effect relationship.
A written document: findings, urgency, recommendations and an indicative cost range.
On request, the structural design of the strengthening — with full design authorisation.
No. Plaster cracks and cracks caused by shrinkage or thermal movement are usually harmless. Diagonal or stepped cracks, cracks starting from the corners of openings and cracks that widen over time, however, indicate structural movement — those have to be investigated.
Only an investigation can answer that. To establish whether a wall is load-bearing, the span direction of the slab and the structural system of the building have to be surveyed. If the wall is load-bearing, a replacement beam can be designed — which requires a structural design authorisation.
Rapid Visual Screening is a fast, non-destructive screening method that allows the earthquake vulnerability of a large number of buildings to be estimated with proportionate effort. It is suitable for reviewing building portfolios (e.g. a municipal estate) and identifies where a detailed assessment is justified.
Yes, for access — and it is useful, because the occupier knows most about how the damage has developed over time. An inspection usually takes 1–3 hours.
Impartial expert opinions for courts and legal disputes (register no. 291469).
DetailsIndependent site supervision and quality control in Győr and beyond.
DetailsMandatory corporate energy audits (EA) and building energy certification.
DetailsSend a few photographs and a short description — we will tell you what assessment is justified.
Follow us:
For a quotation or further information, send us an e-mail or give us a call.