Dr. Orsolya Kegyes-Brassai — forensic engineering expert
Area of expertise

Structural assessment and building diagnostics

Cracks, damage, load-bearing questions and seismic assessment — from the visible symptom to the cause, and from there to the solution.

Cracks, damage, load-bearing capacity and the assessment of existing structures; cause-and-effect analysis with repair and strengthening proposals. Lead structural designer authorisation (T).

A structural opinion is only worth having if it does more than describe the defect: it has to explain what caused it, whether it is dangerous now and what the proportionate intervention is. The investigation always covers the structural system as a whole — a crack is rarely an isolated phenomenon.

The practical expert work is complemented by a university research background: at Széchenyi István University I work on the seismic vulnerability of the existing building stock, on rapid visual screening (RVS) methodology and on pushover analysis.

When is a structural assessment needed?

  • A crack has appeared in a wall, a slab or a façade and it is not clear whether it is still moving.
  • Before demolishing a load-bearing wall, cutting an opening in a slab or converting a loft.
  • For a technical due diligence survey before buying a property.
  • When a change of use or an added storey increases the loads on the structure.
  • After an incident (water ingress, fire, impact, vibration loading, ground movement).
  • To assess the earthquake resistance of an existing building (RVS or detailed analysis).

Scope of the investigation

  • Site inspection, structural survey, crack mapping and photographic documentation.
  • Non-destructive testing and — where needed — opening up and material sampling.
  • Identification of the structural system and verification of load-bearing capacity.
  • Estimation of seismic stability (RVS) or detailed non-linear analysis.
  • Establishing the cause and comparing the strengthening and repair options.
  • Urgency rating: immediate intervention, scheduled repair or monitoring.

How the work proceeds

  1. Preliminary discussion

    On the basis of photographs and a description of the problem we estimate how deep an investigation is justified.

  2. Site survey

    Structural survey, recording of the crack pattern, measurements and opening up where required.

  3. Calculation and assessment

    Verification of load-bearing capacity, modelling and clarification of the cause-and-effect relationship.

  4. Expert opinion

    A written document: findings, urgency, recommendations and an indicative cost range.

  5. Further design

    On request, the structural design of the strengthening — with full design authorisation.

Frequently asked questions

No. Plaster cracks and cracks caused by shrinkage or thermal movement are usually harmless. Diagonal or stepped cracks, cracks starting from the corners of openings and cracks that widen over time, however, indicate structural movement — those have to be investigated.

Only an investigation can answer that. To establish whether a wall is load-bearing, the span direction of the slab and the structural system of the building have to be surveyed. If the wall is load-bearing, a replacement beam can be designed — which requires a structural design authorisation.

Rapid Visual Screening is a fast, non-destructive screening method that allows the earthquake vulnerability of a large number of buildings to be estimated with proportionate effort. It is suitable for reviewing building portfolios (e.g. a municipal estate) and identifies where a detailed assessment is justified.

Yes, for access — and it is useful, because the occupier knows most about how the damage has developed over time. An inspection usually takes 1–3 hours.

Related areas of expertise

Forensic engineering expert services

Impartial expert opinions for courts and legal disputes (register no. 291469).

Details

Construction site supervision

Independent site supervision and quality control in Győr and beyond.

Details

Energy auditing and certification

Mandatory corporate energy audits (EA) and building energy certification.

Details

Structural consultation

Send a few photographs and a short description — we will tell you what assessment is justified.

Request an expert opinion

Contact details

Follow us:

Get in touch

For a quotation or further information, send us an e-mail or give us a call.

This website uses cookies required for its operation and — with your consent — analytics cookies. Details are in the Privacy policy.